Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Cardiothorac Surg ; 19(1): 196, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600556

RESUMEN

BACKGROUND: The transcarotid (TC) vascular access for transcatheter aortic valve implantation (TAVI) has emerged as the first-choice alternative to the transfemoral access, in patients unsuitable for the latter. The use of both the left and right common carotid arteries (CCAs) for TC-TAVI has been described, but the optimal side is subject to debate. We conducted this pilot study to compare the level of vessel tortuosity and plaque burden from either the left CCA to the aortic annulus, or the right CCA to the aortic annulus, considering them as surrogates for technical and procedural complexity. METHODS: Consecutive patients who underwent TC-TAVI between 2018 and 2021 in our institution were included. Using three-dimensional reconstruction, pre-TAVI neck and chest computed tomography angiography exams were reviewed to assess the tortuosity index (TI), sum of angles metric, as well as plaque burden, between each CCA and the aortic annulus. RESULTS: We included 46 patients who underwent TC-TAVI. No significant difference regarding the mean TIs between the left and right sides (respectively 1.20 and 1.19, p = 0.82), the mean sum of angles (left side: 396°, right side: 384°, p = 0.27), and arterial plaque burden (arterial plaque found in 30% of left CCAs and 45% of right CCAs, p = 0.19) was found. CONCLUSIONS: We found no convincing data favoring the use of one particular access side over the other one. The choice of the CCA side in TC-TAVI should to be made on a case-by-case basis, in a multidisciplinary fashion, and may also depend on the operators' experience.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Proyectos Piloto , Arteria Carótida Común/cirugía , Resultado del Tratamiento
2.
EuroIntervention ; 20(8): e496-e503, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629422

RESUMEN

BACKGROUND: Multidisciplinary Heart Teams (HTs) play a central role in the management of valvular heart diseases. However, the comprehensive evaluation of patients' data can be hindered by logistical challenges, which in turn may affect the care they receive. AIMS: This study aimed to explore the ability of artificial intelligence (AI), particularly large language models (LLMs), to improve clinical decision-making and enhance the efficiency of HTs. METHODS: Data from patients with severe aortic stenosis presented at HT meetings were retrospectively analysed. A standardised multiple-choice questionnaire, with 14 key variables, was processed by the OpenAI Chat Generative Pre-trained Transformer (GPT)-4. AI-generated decisions were then compared to those made by the HT. RESULTS: This study included 150 patients, with ChatGPT agreeing with the HT's decisions 77% of the time. The agreement rate varied depending on treatment modality: 90% for transcatheter valve implantation, 65% for surgical valve replacement, and 65% for medical treatment. CONCLUSIONS: The use of LLMs offers promising opportunities to improve the HT decision-making process. This study showed that ChatGPT's decisions were consistent with those of the HT in a large proportion of cases. This technology could serve as a failsafe, highlighting potential areas of discrepancy when its decisions diverge from those of the HT. Further research is necessary to solidify our understanding of how AI can be integrated to enhance the decision-making processes of HTs.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Humanos , Inteligencia Artificial , Estudios Retrospectivos , Corazón , Estenosis de la Válvula Aórtica/cirugía
3.
Int J Legal Med ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594500

RESUMEN

High-risk coronary plaques (HRP) are characterized in clinical radiological imaging by the presence of low plaque attenuation, a napkin-ring sign (NRS), spotty calcifications (SC) and a positive remodeling index (RI). To evaluate if these signs are detectable in postmortem imaging by a multi-phase postmortem CT angiography (MPMCTA), a retrospective study of a series of autopsy well-documented coronary plaques related to sudden cardiac death (SCD) was performed. Then correlations between histological and radiological findings were described. Fourty SCD cases due to acute coronary syndrome based on clinical history and confirmed at autopsy were selected (28 men and 12 women, age 53.3 ± 10.9). The culprit lesion was mainly situated in the proximal segments of coronary arteries, in the right coronary artery in 23 cases (57.5%), the left anterior descending artery in 13 cases (32.5%), the circumflex artery in 3 cases (7.5%) and in one case in the left main stem. MPMCTA showed a positive RI (≥ 1.1) in 75% of cases with a mean RI 1.39 ± 0.71. RI values were lower in cases with fibrotic plaques. NRS was observed in 40% of cases, low attenuation plaque in 46.3%, and SC in 48.7% of cases. There were significant correlations of the radiological presence of NRS for fibrolipid composition of the plaque (p-value 0.007), severe intraplaque inflammation (p-value 0.017), severe adventitial inflammation (p-value 0.021) and an increased vasa vasorum (p-value 0.012). A significant correlation (p-value 0.002) was observed between the presence of SC at radiological examination and the presence of punctuate/fragmented calcification at histology. In addition, in 58.3% of cases, plaque enhancement was observed, which correlated with plaque inflammation and the fibrolipid composition of the plaque. The coronary artery calcium score was 314 (± 455). There was a poor agreement between stenosis of the lumen at histology versus radiology. Our study shows that the various radiological signs of HRP can be detected in all plaques by MPMCTA, but individually only to a variable extent; plaque enhancement appeared as a new sign of vulnerability. In the postmortem approach, these radiological markers of HRP, should always be applied in combination, which can be useful for developing a predictive model for diagnosing coronary SCD.

5.
Eur Radiol ; 34(3): 1755-1763, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658143

RESUMEN

OBJECTIVES: To evaluate the diagnostic utility of multiphase postmortem CT angiography (PMCTA) to detect plaque enhancement as a surrogate marker of inflammation, using fatal coronary plaques obtained from autopsies following sudden cardiac death. METHODS: In this retrospective study, we included 35 cases (12 women, 34%; median [IQR] age, 52 [11] years), with autopsy-proven coronary thrombosis, histological examination, and multiphase PMCTA. Two radiologists blinded towards histological findings assessed PMCTA for plaque enhancement of the culprit lesion in consensus. Two forensic pathologists determined the culprit lesion and assessed histological samples in consensus. Cases with concomitant vasa vasorum density increase and intraplaque and periadventital inflammation were considered positive for plaque inflammation. Finally, we correlated radiology and pathology findings. RESULTS: All 35 cases had histological evidence of atherosclerotic plaque disruption and thrombosis; 30 (85.7%) had plaque inflammation. Plaque enhancement at multiphase PMCTA was reported in 21 (60%) and resulted in a PPV of 95.2% (77.3-99.2%) and an NPV of 28.6% (17-43.9%). Median histological ratings indicated higher intraplaque inflammation (p = .024) and vasa vasorum density (p = .032) in plaques with enhancement. We found no evidence of a difference in adventitial inflammation between CT-negative and CT-positive plaques (p = .211). CONCLUSIONS: Plaque enhancement was found in 2/3 of fatal atherothrombotic occlusions at coronary postmortem CT angiography. Furthermore, plaque enhancement correlated with histopathological plaque inflammation and increased vasa vasorum density. Plaque enhancement on multiphase CT angiography could potentially serve as a noninvasive marker of inflammation in high-risk populations. CLINICAL RELEVANCE STATEMENT: Phenotyping coronary plaque more comprehensively is one of the principal challenges cardiac imaging is facing. Translating our ex vivo findings of CT-based plaque inflammation assessment into clinical studies might help pave the way in defining high-risk plaque better. KEY POINTS: • Most thrombosed coronary plaques leading to fatality in our series had histological signs of inflammation. • Multiphase postmortem CT angiography can provide a noninvasive interrogation of plaque inflammation through contrast enhancement. • Atherosclerotic plaque enhancement at multiphase postmortem CT angiography correlated with histopathological signs of plaque inflammation and could potentially serve as an imaging biological marker of plaque vulnerability.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Femenino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Estudios Retrospectivos , Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X , Inflamación/diagnóstico por imagen , Autopsia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología
6.
Front Cardiovasc Med ; 10: 1276738, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37942065

RESUMEN

Introduction: To evaluate a reduced iodine volume protocol for lower extremity CT angiography (CTA) using dual-energy CT (DECT). Methods: This retrospective study included consecutive patients who underwent lower extremity CTA from June to December 2022. A 10 ml 1:1 mixed test bolus was performed, followed by a 40 ml full bolus at a 2.5/s injection rate, using 400 mg/ml iodine contrast media. Conventional and 40 keV virtual monoenergetic images (VMI) were reconstructed. For both reconstructions, five main artery segments were assessed with a 3-point image quality score as well as quantitative attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements with diagnostic quality thresholds (respectively >150 HU and >3). Results: Forty patients were included in the study (mean age 68 ± 12 yo). 200 artery segments were assessed. Median qualitative image scores were 3 [IQR, 3, 3] for both reconstructions. 40 keV VMI upgraded qualitative scores for 51 (26%) of patients, including 9 (5%) from nondiagnostic to diagnostic quality. 40 keV VMI obtained attenuation and CNR diagnostic quality for respectively 100% and 100% of segments, compared with 96% and 98% for conventional images (p < 0.001). Distal artery segments showed the most differences between 40 keV VMI and conventional images. Conclusion: A low-iodine lower extremity CTA protocol is feasible, with 40 keV virtual monoenergetic spectral reconstruction enabling maintained diagnostic image quality at the distal artery segments.

7.
J Cardiovasc Dev Dis ; 10(10)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37887871

RESUMEN

BACKGROUND: Coronary CT angiography (CCTA) is increasingly used as a non-invasive tool to assess coronary artery disease (CAD). However, CCTA is subject to motion artifacts, potentially limiting its clinical utility. Despite faster (0.35 and 0.28 s/rot) gantry rotation times, low (60-65 bpm) heartbeat is recommended, and the use of ß-blockers is often needed. Technological advancements have resulted in the development of faster rotation speeds (0.23 s/rot). However, their added value in patients not premedicated with ß-blockers remains unclear. This prospective single-center, two-arm, randomized, controlled trial aims to assess the influence of fast rotation on coronary motion artifacts, diagnostic accuracy of CCTA for CAD, and patient safety. METHODS: We will randomize a total of 142 patients aged ≥ 50 scheduled for an aortic stenosis work-up to receive CCTA with either a fast (0.23) or standard (0.28 s/rot) gantry speed. PRIMARY OUTCOME: rate of CCTAs with coronary motion artifacts hindering interpretation. SECONDARY OUTCOMES: assessable coronary segments rate, diagnostic accuracy against invasive coronary angiography (ICA), motion artifact magnitude per segment, contrast-to-noise ratio (CNR), and patient ionizing radiation dose. The local ethics committee has approved the protocol. Potential significance: FAST-CCT may improve motion artifact reduction and diagnosis quality, thus eliminating the need for rate control and ß-blocker administration. CLINICALTRIALS: gov identifier: NCT05709652.

8.
Front Cardiovasc Med ; 10: 1100916, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37273871

RESUMEN

Hepatic microwave ablation (MWA) is a growing treatment modality in the field of primary and secondary liver cancer. One potential side effect is thermal damage to adjacent structures, including the pericardium if the hepatic lesion is located near the diaphragm. Hemorrhagic cardiac tamponade is known to be a rare but potentially life-threatening complication. Here we present the first case of cardiac complication following MWA treatment in a 55-year-old man who presented with late cardiac tamponade. Adequate and timely management is essential, and clinicians should be fully aware of the need to perform early transthoracic echocardiography to detect signs of pericardial effusion when cardiac involvement is suspected.

9.
Eur J Intern Med ; 116: 82-88, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37328399

RESUMEN

BACKGROUND: Embolic events (EEs) are a common complication of infective endocarditis (IE) and their presence can impact diagnosis and modify the therapeutic plan. The present study aimed to describe the role of thoracoabdominal imaging, either thoracoabdominal-pelvic Computed Tomography or 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography, on diagnosis and management of patients with suspected IE. METHODS: This study was conducted at a university hospital, from January 2014 to June 2022. EEs and IE were defined according to modified Duke criteria. RESULTS: Among 966 episodes with suspected IE and thoracoabdominal imaging, 528 (55%) patients were asymptomatic. At least one EE was found in 205 (21%) episodes. Based on thoracoabdominal imaging findings, the diagnosis was reclassified from rejected to possible or from possible to definite IE in 6 (1%) and 10 (1%) episodes, respectively. Among the 413 patients with IE, at least one EE was found on thoracoabdominal imaging in 143 (35%) episodes. Together with the presence of left-side valvular vegetation >10 mm, the results of thoracoabdominal imaging established a surgical indication (prevention of embolism) in 15 (4%) episodes, 7 of which were asymptomatic. CONCLUSIONS: Thoracoabdominal imaging performed in asymptomatic patients with suspected IE improved the diagnosis in only a small proportion of patients. Thoracoabdominal imaging led to a new surgical indication (in association with left-side valvular vegetation >10 mm) in only a small percentage of patients.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Humanos , Endocarditis Bacteriana/complicaciones , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/efectos adversos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Radiofármacos
10.
Front Med (Lausanne) ; 10: 1117151, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37035332

RESUMEN

Background: Pulmonary manifestations of COVID-19 pneumonia are well known. However, COVID-19 is also associated with a range of vascular manifestations such as embolism, congestion, and perfusion changes. Regarding congestion, research from different groups has suggested arteriovenous anastomosis dysregulation as a contributing factor. In this study, we aim to better describe the changes in vascular volume in affected lung zones and to relate them to pathophysiological hypotheses. Methods: We performed automatic vascular volume extraction in 10 chest CTs of patients, including 2 female and 8 male with a mean age of 63.5 ± 9.3 years, diagnosed with COVID-19 pneumonia. We compared the proportion of vascular volumes between manually segmented regions of lung parenchyma with and without signs of pneumonia. Results: The proportion of vascular volume was significantly higher in COVID (CVasc) compared to non-COVID (NCVasc) areas. We found a mean difference (DVasc) of 5% and a mean ratio (RVasc) of 3.7 between the two compartments (p < 0.01). Conclusion: Vascular volume in COVID-19 affected lung parenchyma is augmented relative to normal lung parenchyma, indicating venous congestion and supporting the hypothesis of pre-existing intra-pulmonary arteriovenous shunts.

11.
Biomolecules ; 13(2)2023 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-36830766

RESUMEN

We read with great interest the review by Wang et al. entitled "Identification Markers of Carotid Vulnerable Plaques: An Update", recently published in Biomolecules [...].


Asunto(s)
Arterias Carótidas , Placa Aterosclerótica , Humanos , Imagen por Resonancia Magnética/métodos , Placa Amiloide , Tomografía Computarizada por Rayos X
12.
Front Cardiovasc Med ; 10: 1102063, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36742076

RESUMEN

Pelvic venous disorders (PeVD), sometimes referred to as pelvic congestion syndrome (PCS), widely impact affected patients-mainly young women's quality of life, causing puzzling, uncomfortable symptoms sometimes requiring months or years to get an explanation, while simply remaining undiagnosed in other cases. Because pelvic pain is a non-specific symptom, an appropriate diagnosis requires a careful patient workup, including a correlation between history and non-invasive imaging. Invasive imaging is frequently required to confirm the diagnosis and plan treatment. Current therapeutic approaches principally rely on minimally invasive techniques delivered through endovascular access. However, while comprehensive descriptive classifications such as the symptoms-varices-pathophysiology (SVP) classification exist, universally accepted guidelines regarding therapy to apply for each SVP category are still lacking. This review strongly focuses on PeVD imaging and discusses available therapeutic approaches with regard to pathophysiological mechanisms. It proposes a new classification scheme assisting clinical decision-making about endovascular management to help standardize the link between imaging findings and treatment.

13.
Invest Radiol ; 58(4): 245-252, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36094810

RESUMEN

OBJECTIVES: To assess image noise, diagnostic performance, and potential for radiation dose reduction of photon-counting detector (PCD) computed tomography (CT) with quantum iterative reconstruction (QIR) in the detection of hypoattenuating and hyperattenuating focal liver lesions compared with energy-integrating detector (EID) CT. MATERIALS AND METHODS: A medium-sized anthropomorphic abdominal phantom with liver parenchyma and lesions (diameter, 5-10 mm; hypoattenuating and hyperattenuating from -30 HU to +90 HU at 120 kVp) was used. The phantom was imaged on ( a ) a third-generation dual-source EID-CT (SOMATOM Force, Siemens Healthineers) in the dual-energy mode at 100 and 150 kVp with tin filtration and ( b ) a clinical dual-source PCD-CT at 120 kVp (NAEOTOM Alpha, Siemens). Scans were repeated 10 times for each of 3 different radiation doses of 5, 2.5, and 1.25 mGy. Datasets were reconstructed as virtual monoenergetic images (VMIs) at 60 keV for both scanners and as linear-blended images (LBIs) for EID-CT. For PCD-CT, VMIs were reconstructed with different strength levels of QIR (QIR 1-4) and without QIR (QIR-off). For EID-CT, VMIs and LBIs were reconstructed using advanced modeled iterative reconstruction at a strength level of 3. Noise power spectrum was measured to compare image noise magnitude and texture. A channelized Hotelling model observer was used to assess diagnostic accuracy for lesion detection. The potential for radiation dose reduction using PCD-CT was estimated for the QIR strength level with the highest area under the curve compared with EID-CT for each radiation dose. RESULTS: Image noise decreased with increasing QIR level at all radiation doses. Using QIR-4, noise reduction was 41%, 45%, and 59% compared with EID-CT VMIs and 12%, 18%, and 33% compared with EID-CT LBIs at 5, 2.5, and 1.25 mGy, respectively. The peak spatial frequency shifted slightly to lower frequencies at higher QIR levels. Lesion detection accuracy increased at higher QIR levels and was higher for PCD-CT compared with EID-CT VMIs. The improvement in detection with PCD-CT was strongest at the lowest radiation dose, with an area under the receiver operating curve of 0.917 for QIR-4 versus 0.677 for EID-CT VMIs for hyperattenuating lesions, and 0.900 for QIR-4 versus 0.726 for EID-CT VMIs for hypoattenuating lesions. Compared with EID-CT LBIs, detection was higher for QIR 1-4 at 2.5 mGy and for QIR 2-4 at 1.25 mGy (eg, 0.900 for QIR-4 compared with 0.854 for EID-CT LBIs at 1.25 mGy). Radiation dose reduction potential of PCD-CT with QIR-4 was 54% at 5 mGy compared with VMIs and 39% at 2.5 mGy compared with LBIs. CONCLUSIONS: Compared with EID-CT, PCD-CT with QIR substantially improved focal liver lesion detection, especially at low radiation dose. This enables substantial radiation dose reduction while maintaining diagnostic accuracy.


Asunto(s)
Reducción Gradual de Medicamentos , Neoplasias Hepáticas , Humanos , Fotones , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Neoplasias Hepáticas/diagnóstico por imagen
15.
Quant Imaging Med Surg ; 12(7): 3903-3916, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35782242

RESUMEN

Background: Dual-energy dual-layer computed tomography (CT) scanners can provide useful tools, such as iodine maps and virtual monochromatic images (VMI), for the evaluation of myocardial perfusion defects. Data about the influence of acquisition protocols and normal values are still lacking. Methods: Clinically indicated coronary CT-angiographies performed between January-October 2018 in a single university hospital with dual-energy dual-layer CT (DE-DLCT) and different injection protocols were retrospectively evaluated. The two protocols were: 35 mL in patients <80 kg and 0.5 mL/kg in patients >80 kg at 2.5 mL/s (group A) or double contrast dose at 5 mL/s (group B). Patients with coronary stenosis >50% were excluded. Regions of interest were manually drawn on 16 myocardial segments and iodine concentration was measured in mg/mL. Signal-to-noise, contrast-to-noise ratios (CNR) and image noise were measured on conventional images and VMI. Results: A total of 30 patients were included for each protocol. With iodine concentrations of 1.38±0.41 mg/mL for protocol A and 2.07±0.73 mg/mL for protocol B, the two groups were significantly different (P<0.001). No significant iodine concentration differences were found between the 16 segments (P=0.47 and P=0.09 for group A and B respectively), between basal, mid and apical segments for group A and B (P=0.28 and P=0.12 for group A and B respectively) and between wall regions for group A (P=0.06 on normalised data). In group B, iodine concentration was significantly different between three wall regions [highest values for the lateral wall, median =2.03 (1.06) mg/mL]. Post-hoc analysis showed highest contrast-to-noise and signal-to-noise in VMI at 40 eV (P<0.05). Conclusions: Iodine concentration in left ventricular myocardium of patients without significant coronary artery stenosis varied depending on the injection protocol and appeared more heterogeneous in different wall regions at faster injection rate and greater iodine load. Signal-to-noise and contrast-to-noise gradually improved when decreasing VMI energy, although at the expenses of higher noise, demonstrating the potential of DE-DLCT to enhance objective image quality.

16.
Biomedicines ; 10(6)2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35740322

RESUMEN

Background: Vascular abnormalities, including venous congestion (VC) and pulmonary embolism (PE), have been recognized as frequent COVID-19 imaging patterns and proposed as severity markers. However, the underlying pathophysiological mechanisms remain unclear. In this study, we aimed to characterize the relationship between VC, PE distribution, and alveolar opacities (AO). Methods: This multicenter observational registry (clinicaltrials.gov identifier NCT04824313) included 268 patients diagnosed with SARS-CoV-2 infection and subjected to contrast-enhanced CT between March and June 2020. Acute PE was diagnosed in 61 (22.8%) patients, including 17 females (27.9%), at a mean age of 61.7 ± 14.2 years. Demographic, laboratory, and outcome data were retrieved. We analyzed CT images at the segmental level regarding VC (qualitatively and quantitatively [diameter]), AO (semi-quantitatively as absent, <50%, or >50% involvement), clot location, and distribution related to VC and AO. Segments with vs. without PE were compared. Results: Out of 411 emboli, 82 (20%) were lobar or more proximal and 329 (80%) were segmental or subsegmental. Venous diameters were significantly higher in segments with AO (p = 0.031), unlike arteries (p = 0.138). At the segmental level, 77% of emboli were associated with VC. Overall, PE occurred in 28.2% of segments with AO vs. 21.8% without (p = 0.047). In the absence of VC, however, AO did not affect PE rates (p = 0.94). Conclusions: Vascular changes predominantly affected veins, and most PEs were located in segments with VC. In the absence of VC, AOs were not associated with the PE rate. VC might result from increased flow supported by the hypothesis of pulmonary arteriovenous anastomosis dysregulation as a relevant contributing factor.

17.
Front Med (Lausanne) ; 9: 858731, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35573012

RESUMEN

Rationale and Objectives: Computed tomography (CT) lung nodule assessment is routinely performed and appears very promising for lung cancer screening. However, the radiation exposure through time remains a concern. With the overall goal of an optimal management of indeterminate lung nodules, the objective of this prospective study was therefore to evaluate the potential of optimized ultra-short echo time (UTE) MRI for lung nodule detection and volumetric assessment. Materials and Methods: Eight (54.9 ± 13.2 years) patients with at least 1 non-calcified nodule ≥4 mm were included. UTE under high-frequency non-invasive ventilation (UTE-HF-NIV) and in free-breathing at tidal volume (UTE-FB) were investigated along with volumetric interpolated breath-hold examination at full inspiration (VIBE-BH). Three experienced readers assessed the detection rate of nodules ≥4 mm and ≥6 mm, and reported their location, 2D-measurements and solid/subsolid nature. Volumes were measured by two experienced readers. Subsequently, two readers assessed the detection and volume measurements of lung nodules ≥4mm in gold-standard CT images with soft and lung kernel reconstructions. Volumetry was performed with lesion management software (Carestream, Rochester, New York, USA). Results: UTE-HF-NIV provided the highest detection rate for nodules ≥4 mm (n = 66) and ≥6 mm (n = 32) (35 and 50%, respectively). No dependencies were found between nodule detection and their location in the lung with UTE-HF-NIV (p > 0.4), such a dependency was observed for two readers with VIBE-BH (p = 0.002 and 0.03). Dependencies between the nodule's detection and their size were noticed among readers and techniques (p < 0.02). When comparing nodule volume measurements, an excellent concordance was observed between CT and UTE-HF-NIV, with an overestimation of 13.2% by UTE-HF-NIV, <25%-threshold used for nodule's growth, conversely to VIBE-BH that overestimated the nodule volume by 28.8%. Conclusion: UTE-HF-NIV is not ready to replace low-dose CT for lung nodule detection, but could be used for follow-up studies, alternating with CT, based on its volumetric accuracy.

18.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35621848

RESUMEN

Advances in computed tomography (CT) have resulted in a substantial increase in the size of datasets. We built a new concept of medical image compression that provides the best compromise between compression rate and image quality. The method is based on multiple contexts and regions-of-interest (ROI) defined according to the degree of clinical interest. High priority areas (primary ROIs) are assigned a lossless compression. Other areas (secondary ROIs and background) are compressed with moderate or heavy losses. The method is applied to a whole dataset of CT angiography (CTA) of the lower extremity vasculature. It is compared to standard lossy compression techniques in terms of quantitative and qualitative image quality. It is also compared to standard lossless compression techniques in terms of image size reduction and compression ratio. The proposed compression method met quantitative criteria for high-quality encoding. It obtained the highest qualitative image quality rating score, with a statistically significant difference compared to other methods. The average compressed image size was up to 61% lower compared to standard compression techniques, with a 9:1 compression ratio compared with original non-compressed images. Our new adaptive 3D compression method for CT images can save data storage space while preserving clinically relevant information.

19.
Microbiol Spectr ; 10(3): e0037922, 2022 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-35583335

RESUMEN

Timely identification of a pathogen in lower respiratory tract infections (LRTI) can support appropriate antibiotics use. The difficulty of obtaining lower respiratory tract (LRT) samples limits the utility of point-of-care syndromic molecular assays. We assessed the performance of the FilmArray Pneumonia plus panel (FilmArray PP) in nasopharyngeal (NP) swab for detection of Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis. Patients in the study included retrospectively consenting adults who attended the emergency department of Lausanne University Hospital between February 2019 and August 2020 for a community-acquired LRTI, with available NP swab and a high-quality LRT sample. These samples were tested with the FilmArray PP (cutoff of ≥104 copies/mL). Positive (PPA) and negative percent agreement (NPA) of FilmArray PP in NP swab were calculated, using (i) FilmArray PP in LRT sample and (ii) standard microbiological tests as reference standards. To assess the performance of a lower detection cutoff, NP samples were also tested with an in-house PCR (cutoff of ≥10 copies/mL) for S. pneumoniae and H. influenzae. Overall, 118 patients were included. FilmArray PP in LRT sample and standard microbiology tests detected S. pneumoniae in 19/118 and 12/118, H. influenzae in 44/118 and 19/118, and M. catarrhalis in 14/118 and 0/118, respectively. Using LRT FilmArray PP as reference, PPA and NPA of FilmArray PP on NP were 58% and 100% for S. pneumoniae, 61% and 100% for H. influenzae, and 57% and 99% for M. catarrhalis. Using standard diagnostic tests as reference, PPA and NPA were 58% and 96% for S. pneumoniae, 74% and 87% for H. influenzae, and indefinite and 92% for M. catarrhalis. Using a lower cutoff on NP (≥102 copies/mL), PPA was 68% for S. pneumoniae and 77% for H. influenzae with LRT FilmArray PP as reference. FilmArray PP in NP swabs has a limited PPA for identifying the most common etiologies of community-acquired LRTI irrespective of the reference standard, preventing its use for withholding antibiotics. The PCR detection cutoff does not explain the low PPA. The excellent NPA suggests the use of NP PCR results for rapidly targeted antimicrobial therapy. IMPORTANCE Timely identification of a pathogen in patients with lower respiratory tract infections is of paramount importance to avoid inappropriate antibiotic prescription. We aimed to evaluate the performance of a rapid syndromic molecular assay in nasopharyngeal swabs for identifying the most common bacterial causes of lower respiratory tract infections in adults (Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis). Our data show that nasopharyngeal molecular assay has a good concordance with lower respiratory tract sample when positive but not when negative. A positive result is therefore concordant with a lower respiratory tract infection and can be used to target antibiotics. Nevertheless, a negative result does not have a good concordance, so it cannot be used to withhold antibiotics. Our findings illustrate the potential utility of these easily collected samples for the management of patients with lower respiratory tract infections.


Asunto(s)
Infecciones Comunitarias Adquiridas , Neumonía , Infecciones del Sistema Respiratorio , Adulto , Antibacterianos/farmacología , Bacterias , Infecciones Comunitarias Adquiridas/diagnóstico , Infecciones Comunitarias Adquiridas/microbiología , Haemophilus influenzae/genética , Humanos , Moraxella catarrhalis/genética , Nasofaringe/microbiología , Neumonía/microbiología , Reacción en Cadena de la Polimerasa , Infecciones del Sistema Respiratorio/microbiología , Estudios Retrospectivos , Streptococcus pneumoniae/genética
20.
Eur J Radiol ; 150: 110259, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35334245

RESUMEN

PURPOSE: It is known from histology studies that lung vessels are affected in viral pneumonia. However, their diagnostic potential as a chest CT imaging parameter has only rarely been exploited. The purpose of this study is to develop a robust method for automated lung vessel segmentation and morphology analysis and apply it to a large chest CT dataset. METHODS: In total, 509 non-enhanced chest CTs (NECTs) and 563 CT pulmonary angiograms (CTPAs) were included. Sub-groups were patients with healthy lungs (group_NORM, n = 634) and those RT-PCR-positive for Influenza A/B (group_INF, n = 159) and SARS-CoV-2 (group_COV, n = 279). A lung vessel segmentation algorithm (LVSA) based on traditional image processing was developed, validated with a point-of-interest approach, and applied to a large clinical dataset. Total blood vessel volume in lung (TBV) and the blood vessel volume percentage (BV%) of three blood vessel size types were calculated and compared between groups: small (BV5%, cross-sectional area < 5 mm2), medium (BV5-10%, 5-10 mm2) and large (BV10%, >10 mm2). RESULTS: Sensitivity of the LVSA was 84.6% (95 %CI: 73.9-95.3) for NECTs and 92.8% (95 %CI: 90.8-94.7) for CTPAs. In viral pneumonia, besides an increased TBV, the main finding was a significantly decreased BV5% in group_COV (n = 14%) and group_INF (n = 15%) compared to group_NORM (n = 18%) [p < 0.001]. At the same time, BV10% was increased (group_COV n = 15% and group_INF n = 14% vs. group_NORM n = 11%; p < 0.001). CONCLUSION: In COVID-19 and Influenza, the blood vessel volume is redistributed from small to large vessels in the lung. Automated LSVA allows researchers and clinicians to derive imaging parameters for large amounts of CTs. This can enhance the understanding of vascular changes, particularly in infectious lung diseases.


Asunto(s)
COVID-19 , Gripe Humana , Neumonía Viral , Humanos , Gripe Humana/diagnóstico por imagen , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...